Features and Benefits of ADCOLE Model 1300

Features and Benefits of the ADCOLE Model 1300:

  • Can handle up to 39" (1000 mm) length part (optional lengths are available)
  • Capable of measuring as many as 24 features (lobes and journals)
  • Measuring times between 50 to 65 seconds, depending on the size of the part
  • Modular design for easy and maintenance
  • Easy follower relocation for part variations
  • 3600 data points per revolution per follower
  • User-friendly software and programming menus
  • Shop floor-hardened design
  • Full length/wisth preceision granite surface plate
  • Programmable reporting
  • Automation communication and integration

Available Options:

  • Programmable part elevator for accurate load/unload of parts into gage
  • Clean and calibration bars are loaded/unloaded by the robot or gantry. Used to insert a cleaning bar for the follower tips than a calibration check of the gage
  • Part identification
  • LVDT nest for measuring spacing, flatness and runout of thrustfaces
  • Chatter Analysis Software for monitoring grinders and machining

Crankshaft Measurement Parameters:

  • Main and pin journal diameter, measured at three locations per journal (over oil holes were required). Accommodates journals of different diameters within the same part.
  • Main and pin journal circularity (roundness) with LSC, MZC, (MRS), MIC and MCC circle evaluation methods according to ISO 6318
  • Lobing evaluation over 360 degrees with selectable sliding window
  • Main and pin journal cylindricity
  • Main and pin journal straightness (linear profile) and barreling
  • Main and pin journal taper
  • Main and pin journal parallelism
  • Main and pin journal center deviation
  • Main journal thrustface radial and face runout
  • Main journal concentricity/eccentricity and part bow correction to end journals
  • Pin journal angular position (index error)
  • Pin journal throw and true position
  • Linear error plots or polar plots to CRT or printer with refence circle
  • Calibration verification and temperature compensation


© Copyright Adcole Corp, 2007, All Rights Reserved.